ToolBB-0321

Inspector Watt: firmware power profiling on a Nordic PPK2 with an MCP server

Inspector Watt records a device's current with a Nordic PPK2 at 100,000 samples per second and lines it up with the firmware's UART log. An MCP server exposes sessions, log search, cycle summaries and battery-life estimates to agents such as Claude Code. The example target is a Seeed XIAO ESP32-C6; the README screenshots come from its simulator.

Open original source github.com · mcpijnappel

Claimed
Why this evidence label?

README gives timing figures for a XIAO ESP32-C6 and setup notes, but its screenshots are labeled as simulator output; no real captures shown.

How we check entries
Preview image for Inspector Watt: firmware power profiling on a Nordic PPK2 with an MCP server
The source's own preview image, from github.com.

Briefing

The PPK2 runs in source mode and powers the device under test through its battery pins. Log lines mark the phases of each wake-up (boot, measure, connect, upload, sleep), and a web UI breaks the current trace down by phase.

Hardware control over MCP (power, recording, the USB console) is off by default. Turning it on takes a per-session allow in the web UI and a confirmation flag on each call. Flashing goes through PlatformIO with a separate token, not through MCP.

Tags

Board
Instrument

Report a problem with this entry